Parker Standard Pilot Vented Load Control Valves (MHC022VCSE00B)
Part Number
MHC-022-VCSE-00B
Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Seal Material | Nitrile, Nitrile |
---|---|
Port Size | N/A, N/A |
Adjustment Mechanism | Standard (adjustable), Standard (adjustable) |
Mounting Type | Threaded Cartridge Valve, Threaded Cartridge Valve |
Holding Pressure | 1500 PSI, 105 BAR, 105 bar, 1500 psi |
Pressure Control Range | N/A, N/A bar, N/A psi |
Maximum Flow Rate | 25 GAL/MIN, 93.75 L/MIN, 25 Gal/min, 93.75 L/min |
Pilot Pressure Ratio | 5:1, 5:1 |
Operating Temperature | -34 to +121 °C, -30 to +250 °F |
Division | Hydraulic Cartridge Systems Division |
For Fluid Type | Mineral-based or synthetic hydraulic fluids |
Installation Torque | 75-80 lb-ft, 102-108 Nm |
Minimum Operating Temperature | -30 °F, -34 °C |
Actuation Type | Pilot Operated, Vented |
Leak Rate | 5 @ 80% of setting drops/min |
Flow Direction | Cylinder port 2, Valve port 3, Pilot port 1 |
Maximum Operating Pressure | 350 bar, 5000 psi |
Pilot Location | External |
Function | Counterbalance Valve |
Weight | 0.38 kg, 0.88 lb |
Cavity Size | CDD-1036 |
Pressure Control Sensitivity | N/A psi, N/A bar |
Filter Efficiency Rating | ISO 4406 18/16/13, SAE Class 4 |
Maximum Operating Temperature | +250 °F, +121 °C |
Maximum Inlet Pressure Rating | 350 bar, 5000 psi |
Valve Material | All parts steel. All operating parts hardened steel |
Flow Rate | 93.75 L/min, 25 Gal/min |
Maximum Kinematic Viscosity | 45-2000 SSU (6 to 420 cSt) |
Body Material | N/A |