Parker Standard Pilot Assisted Load Control Valves (CB101BT30V)

Part Number
CB101BT30V

Whoops! We need to check the price of this item. Request a Quote and we will be back to you within 24 hours. or Call 01332 851300 8am. - 5pm. Monday to Friday

Parker’s piloted load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open based off a given backpressure specific to the application, which could be much lower than the spring pressure setting. This feature allows predictable and consistent control of a load throughout its lowering cycle.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios 8:1 to 1.5:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
It should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability. The valve will be affected by backpressure and care must be taked with proportional and closed center systems.
Technical Specification
Port Size N/A, N/A
Seal Material Fluorocarbon, Fluorocarbon
Pressure Control Range 2400-5000 PSI, 166-350 BAR, 166-350 bar, 2400-5000 psi
Holding Pressure 3000 PSI, 210 BAR, 210 bar, 3000 psi
Maximum Flow Rate 12 GAL/MIN, 45 L/MIN, 45 L/min, 12 Gal/min
Mounting Type Threaded Cartridge Valve, Threaded Cartridge Valve
Adjustment Mechanism Tamper Resistant, Tamper Resistant
Pilot Pressure Ratio 4.5:1, 4.5:1
Division Hydraulic Cartridge Systems Division
Maximum Kinematic Viscosity 45-2000 SSU (6 to 420 cSt), Mineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cSt
Operating Temperature -26° to +204° °C, -15 to +400 °F, -26 to +204 °C, -15° to +400° °F
Pressure Control Sensitivity 21.2 per turn bar, 307 per turn psi, N/A psi, N/A bar
Flow Direction Cylinder port 1, Valve port 2, Pilot port 3
Function Counterbalance Valve
Flow Rate 12 Gal/min, 45 L/min
Pilot Location External
Weight 0.5 lb, 0.23 kg
Maximum Inlet Pressure Rating 5500 psi, 380 bar
Maximum Operating Pressure 5000 psi, 350 bar
Leak Rate 5 @ 80% of setting drops/min
Valve Material All parts steel. All operating parts hardened steel
Installation Torque 16 lb-ft, 22 Nm
Body Material N/A
Filter Efficiency Rating ISO 4406:1999 Code 18/16/13, ISO 4406 18/16/13, SAE Class 4
Actuation Type Pilot Operated
Maximum Operating Temperature +400 °F, +204 °C
Minimum Operating Temperature -26 °C, -15 °F
Cavity Size C10-3
Port Thread Size N/A
For Fluid Type Mineral-based or synthetic hydraulic fluids