Parker Standard Pilot Assisted Load Control Valves (CB101BT30)
Part Number
CB101BT30
Parker’s piloted load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 420 bar (6000 psi) and flows up to 350 lpm (90 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open based off a given backpressure specific to the application, which could be much lower than the spring pressure setting. This feature allows predictable and consistent control of a load throughout its lowering cycle.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios 8:1 to 1.5:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
It should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability. The valve will be affected by backpressure and care must be taked with proportional and closed center systems.
Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
Features/Benefits:
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios 8:1 to 1.5:1
• All external parts zinc plated
Applications:
• Load holding
• Position holding
Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
It should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability. The valve will be affected by backpressure and care must be taked with proportional and closed center systems.
Port Size | N/A, N/A |
---|---|
Pressure Control Range | 2400-5000 PSI, 166-350 BAR, 166-350 bar, 2400-5000 psi |
Maximum Flow Rate | 12 GAL/MIN, 45 L/MIN, 45 L/min, 12 Gal/min |
Mounting Type | Threaded Cartridge Valve, Threaded Cartridge Valve |
Seal Material | Nitrile, Nitrile |
Adjustment Mechanism | Tamper Resistant, Tamper Resistant |
Holding Pressure | 3000 PSI, 210 BAR, 210 bar, 3000 psi |
Pilot Pressure Ratio | 4.5:1, 4.5:1 |
Maximum Operating Pressure | 350 bar, 5000 psi |
Maximum Operating Temperature | +121 °C, +250 °F |
Actuation Type | Pilot Operated |
Pressure Control Sensitivity | N/A bar, 21.2 per turn bar, 307 per turn psi, N/A psi |
Leak Rate | 5 @ 80% of setting drops/min |
Valve Material | All parts steel. All operating parts hardened steel |
Function | Counterbalance Valve |
Pilot Location | External |
Minimum Operating Temperature | -34 °C, -30 °F |
Flow Rate | 12 Gal/min, 45 L/min |
Filter Efficiency Rating | ISO 4406:1999 Code 18/16/13, ISO 4406 18/16/13, SAE Class 4 |
Maximum Kinematic Viscosity | Mineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cSt, 45-2000 SSU (6 to 420 cSt) |
Body Material | N/A |
Operating Temperature | -34° to +121° °C, -30° to +250° °F, -30 to +250 °F, -34 to +121 °C |
Installation Torque | 16 lb-ft, 22 Nm |
Port Thread Size | N/A |
For Fluid Type | Mineral-based or synthetic hydraulic fluids |
Cavity Size | C10-3 |
Maximum Inlet Pressure Rating | 5500 psi, 380 bar |
Weight | 0.5 lb, 0.23 kg |
Division | Hydraulic Cartridge Systems Division |
Flow Direction | Cylinder port 1, Valve port 2, Pilot port 3 |